Skip to product information
1 of 3

ProSoft MVI56-HART HART Multi-drop Master Communication Module

ProSoft MVI56-HART HART Multi-drop Master Communication Module

  • Manufacturer: ProSoft

  • Product No.: MVI56-HART

  • Condition:1000 in stock

  • Product Type: HART Multi-drop Master Communication Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Information

Manufacturer

Prosoft

Model/Part Number

MVI56-HART

Description

HART Multi-drop Master Communication Module

General Specifications

 Single-slot, 1756 backplane-compatible

 Recognized as an Input/Output module with access to processor memory for data transfer

 Data transfer between module and processor managed via Ladder Logic (sample ladder file included)

 Configuration data obtained from a configuration text file downloaded to the module (sample configuration file included)

 Can be installed in local or remote racks


Hardware Specifications

Specification

Description

Backplane Current Load

800 mA @ 5 V DC  3 mA @ 24 V DC

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Shock

30g Operational  50g Non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (non-condensing)

LED Indicators

- Module Status  - Backplane Transfer Status  - Application Status  - Serial Activity

Debug/Configuration Port (CFG)

RJ45 (DB-9M with supplied cable)  RS-232 only  No hardware handshaking

Configuration Connector

RJ45 RS-232 Connector (RJ45 to DB-9 cable shipped with unit)

Application Ports

AppPort HART terminal connector

 

View full details

Product Description

General Information

Manufacturer

Prosoft

Model/Part Number

MVI56-HART

Description

HART Multi-drop Master Communication Module

General Specifications

 Single-slot, 1756 backplane-compatible

 Recognized as an Input/Output module with access to processor memory for data transfer

 Data transfer between module and processor managed via Ladder Logic (sample ladder file included)

 Configuration data obtained from a configuration text file downloaded to the module (sample configuration file included)

 Can be installed in local or remote racks


Hardware Specifications

Specification

Description

Backplane Current Load

800 mA @ 5 V DC  3 mA @ 24 V DC

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Shock

30g Operational  50g Non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (non-condensing)

LED Indicators

- Module Status  - Backplane Transfer Status  - Application Status  - Serial Activity

Debug/Configuration Port (CFG)

RJ45 (DB-9M with supplied cable)  RS-232 only  No hardware handshaking

Configuration Connector

RJ45 RS-232 Connector (RJ45 to DB-9 cable shipped with unit)

Application Ports

AppPort HART terminal connector

 

Download PDF file here: