Honeywell XLS3000-CPUD Intelligent Addressable Fire Alarm System

Honeywell XLS3000-CPUD Intelligent Addressable Fire Alarm System

  • Manufacturer: HONEYWELL

  • Product No.: XLS3000-CPUD

  • Condition:1000 in stock

  • Product Type: Intelligent Addressable Fire Alarm System

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 2700g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Overview

Manufacturer: Honeywell
Model/Part Number: XLS3000-CPUD
Description: Intelligent Addressable Fire Alarm System


System Capacity

  • Signaling Line Circuits (SLCs): 1 (expandable up to 10)
  • Intelligent Detectors: 159 per loop
  • Addressable Monitor/Control Modules: 159 per loop
  • Programmable Software Zones: Over 2,000
  • Annunciators Supported per CPU: 32 (each with up to 64 or 96 points)
    • Maximum Annunciator Address Points per ACM24AT/-48A: 96

Electrical Specifications

Parameter Specification
Model XLS3000 Intelligent Addressable Fire Alarm System
Primary Input Power
AMPS-24 110-120 VAC, 50/60 Hz, 4.5 A max
AMPS-24E 240 VAC, 50/60 Hz, 2.25 A max
DC Output
24 VDC Up to 4.5 A
5 VDC Up to 1.0 A
Current Draw (Standby/Alarm)
XLS3000-CPUD Board 0.340 A
XLS3000-CPUND Board 0.120 A
LCM-320 0.130 A
LEM-320 0.100 A
AMPS-24(E)* 0.13 A (Draws power from secondary power source only)
Total Output Power 24V, 4.5 A in alarm

Note: For detailed power calculations, refer to AMPS-24(E) Manual 51907.


Physical Specifications

Parameter Specification
Temperature Range (Operating) 32°F to 120°F (0°C to 49°C)
Humidity Range 10% to 93% RH, non-condensing
Shipping Weight
XLS3000-CPUD 5.95 lb (2.70 kg)
XLS3000-CPUND 2.90 lb (1.32 kg)

Environmental Conditions & Recommendations

  • Meets NFPA requirements for operation between 0 – 49°C (32 – 120°F) and 93% ± 2% RH (non-condensing at 32°C/90°F).
  • Recommended Installation Environment:
    • Room temperature 15 – 27°C (60 – 80°F) for optimal battery and component lifespan.
View full details

Product Description

Product Overview

Manufacturer: Honeywell
Model/Part Number: XLS3000-CPUD
Description: Intelligent Addressable Fire Alarm System


System Capacity

  • Signaling Line Circuits (SLCs): 1 (expandable up to 10)
  • Intelligent Detectors: 159 per loop
  • Addressable Monitor/Control Modules: 159 per loop
  • Programmable Software Zones: Over 2,000
  • Annunciators Supported per CPU: 32 (each with up to 64 or 96 points)
    • Maximum Annunciator Address Points per ACM24AT/-48A: 96

Electrical Specifications

Parameter Specification
Model XLS3000 Intelligent Addressable Fire Alarm System
Primary Input Power
AMPS-24 110-120 VAC, 50/60 Hz, 4.5 A max
AMPS-24E 240 VAC, 50/60 Hz, 2.25 A max
DC Output
24 VDC Up to 4.5 A
5 VDC Up to 1.0 A
Current Draw (Standby/Alarm)
XLS3000-CPUD Board 0.340 A
XLS3000-CPUND Board 0.120 A
LCM-320 0.130 A
LEM-320 0.100 A
AMPS-24(E)* 0.13 A (Draws power from secondary power source only)
Total Output Power 24V, 4.5 A in alarm

Note: For detailed power calculations, refer to AMPS-24(E) Manual 51907.


Physical Specifications

Parameter Specification
Temperature Range (Operating) 32°F to 120°F (0°C to 49°C)
Humidity Range 10% to 93% RH, non-condensing
Shipping Weight
XLS3000-CPUD 5.95 lb (2.70 kg)
XLS3000-CPUND 2.90 lb (1.32 kg)

Environmental Conditions & Recommendations

  • Meets NFPA requirements for operation between 0 – 49°C (32 – 120°F) and 93% ± 2% RH (non-condensing at 32°C/90°F).
  • Recommended Installation Environment:
    • Room temperature 15 – 27°C (60 – 80°F) for optimal battery and component lifespan.