Skip to product information
1 of 4

Honeywell CC-PAIM01 51405045-175 Low-Level Input Multiplexer

Honeywell CC-PAIM01 51405045-175 Low-Level Input Multiplexer

  • Manufacturer: Honeywell

  • Product No.: 51405045-175

  • Condition:1000 in stock

  • Product Type: Low-Level Input Multiplexer (LLMUX) for Thermocouple and RTD inputs

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Details


 

  • Manufacturer: Honeywell

  • Model/Part Number: CC-PAIM01 51405045-175

  • Description: Low-Level Input Multiplexer (LLMUX) for Thermocouple and RTD inputs


 



 

Detailed Specifications – Low-Level Input Multiplexer


Category

Specification

Model Type

CC-PAIM01 – Low-Level Multiplexer

Compatible PMIO FTA Models

MU-TAMR04, TAMT04, TAMT14

Input Type

Thermocouple (TC) and/or Resistance Temperature Detector (RTD)

Input Channels

64 fully isolated channels (channel-to-channel, to PM, and to power supply); increments of 16

Input Scan Rate

1 second fixed by IOM (up to 64 channels/sec)

Channel Bandwidth

0 to 4.7 Hz (-3 dB)

Nominal Input Range (TC only)

-20 to +100 mV

Max Continuous Input (non-damaging)

TC: -10 to +10 VRTD: -1 to +2 V @ 100 mA

Gain Error

≤ 0.050% of full scale (-20 to +100 mV range)

Temperature Stability

TC/mV: ±20 ppm/°CRTD: ±20 ppm/°C

Long Term Drift

500 ppm

Input Impedance

1 MΩ at DC (TC only)

Common Mode Voltage (CMV)

±250 VDC or VAC RMS (DC to 60 Hz)

Common Mode Rejection Ratio (CMRR)

≥ 120 dB at 50/60 Hz (with 1000 Ω source impedance)

Voltage Isolation (Ch-to-Ch)

±250 VDC or VAC RMS (DC to 60 Hz)

Crosstalk

80 dB typical, 120 dB at 50/60 Hz

Normal Mode Rejection Ratio

≥ 60 dB at 50/60 Hz

Line Frequency Integration

50 Hz or 60 Hz (fixed selection)

RTD Sensor Excitation Current

1 mA

Cold Junction Reference (CJR) Accuracy

0–50°C: ±1.0°C-20–60°C: ±1.5°C

TC Linearization Accuracy

±0.05 Ω/°C

Open TC Detection

≤1000 Ω = guaranteed no trip≥1500 Ω = guaranteed trip

RTD Max Lead Resistance

15 Ω

Surge Protection (Sensor Terminals)

EN 61000-4-5 (1kV line-to-line, 2kV line-to-ground)

Surge Protection (Power/Serial)

EN 61000-4-5 (1kV line-to-line, 2kV line-to-ground)

Max Cable Distance (IOTA to FTA)

1000 ft using 16 AWG, two twisted pairs per FTA

FTA Dimensions

Inches: 2.5 D x 4.9 W x 12.1 Lmm: 63.5 D x 124.46 W x 307.34 L

 

View full details

Product Description

Product Details


 

  • Manufacturer: Honeywell

  • Model/Part Number: CC-PAIM01 51405045-175

  • Description: Low-Level Input Multiplexer (LLMUX) for Thermocouple and RTD inputs


 



 

Detailed Specifications – Low-Level Input Multiplexer


Category

Specification

Model Type

CC-PAIM01 – Low-Level Multiplexer

Compatible PMIO FTA Models

MU-TAMR04, TAMT04, TAMT14

Input Type

Thermocouple (TC) and/or Resistance Temperature Detector (RTD)

Input Channels

64 fully isolated channels (channel-to-channel, to PM, and to power supply); increments of 16

Input Scan Rate

1 second fixed by IOM (up to 64 channels/sec)

Channel Bandwidth

0 to 4.7 Hz (-3 dB)

Nominal Input Range (TC only)

-20 to +100 mV

Max Continuous Input (non-damaging)

TC: -10 to +10 VRTD: -1 to +2 V @ 100 mA

Gain Error

≤ 0.050% of full scale (-20 to +100 mV range)

Temperature Stability

TC/mV: ±20 ppm/°CRTD: ±20 ppm/°C

Long Term Drift

500 ppm

Input Impedance

1 MΩ at DC (TC only)

Common Mode Voltage (CMV)

±250 VDC or VAC RMS (DC to 60 Hz)

Common Mode Rejection Ratio (CMRR)

≥ 120 dB at 50/60 Hz (with 1000 Ω source impedance)

Voltage Isolation (Ch-to-Ch)

±250 VDC or VAC RMS (DC to 60 Hz)

Crosstalk

80 dB typical, 120 dB at 50/60 Hz

Normal Mode Rejection Ratio

≥ 60 dB at 50/60 Hz

Line Frequency Integration

50 Hz or 60 Hz (fixed selection)

RTD Sensor Excitation Current

1 mA

Cold Junction Reference (CJR) Accuracy

0–50°C: ±1.0°C-20–60°C: ±1.5°C

TC Linearization Accuracy

±0.05 Ω/°C

Open TC Detection

≤1000 Ω = guaranteed no trip≥1500 Ω = guaranteed trip

RTD Max Lead Resistance

15 Ω

Surge Protection (Sensor Terminals)

EN 61000-4-5 (1kV line-to-line, 2kV line-to-ground)

Surge Protection (Power/Serial)

EN 61000-4-5 (1kV line-to-line, 2kV line-to-ground)

Max Cable Distance (IOTA to FTA)

1000 ft using 16 AWG, two twisted pairs per FTA

FTA Dimensions

Inches: 2.5 D x 4.9 W x 12.1 Lmm: 63.5 D x 124.46 W x 307.34 L

 