Product Description
General Information
Parameter |
Details |
---|---|
Manufacturer |
General Electric |
Model/Part Number |
IC698PSA100E |
Description |
Power Supplies |
Description
• IC698PSA100 provides up to 100 W total output power at ambient temperatures of 0 to 60ºC without forced air cooling.
• Output Voltages:
• +5 VDC output up to 20 amps
• +12 VDC output up to 2 amps
• -12 VDC output up to 1 amp
Features
• Operation from 85 to 264 VAC, 100 to 150 VDC
• Slide-in rack mount construction
• Electronic short circuit overcurrent protection
• Overcurrent and overvoltage fault protection
• Power factor correction for AC operation
Specifications
Input Requirements
Parameter |
100 W Supply |
350 W Supply |
---|---|---|
Nominal Rated Voltage |
120/240 VAC, 125 VDC |
120/240 VAC, 125 VDC |
Input Voltage Range |
85 to 264 VAC (47-63 Hz), 100-150 VDC |
85 to 264 VAC (47-63 Hz), 100-150 VDC |
Input Power (Typical/Max) |
125 W / 150 W |
437 W / 500 W |
Inrush Current (115 VAC) |
15 A max |
30 A max |
Inrush Current (230 VAC) |
30 A max |
60 A max |
Inrush Current Duration |
100 ms |
100 ms |
Power Factor |
0.99 min (between 90 VAC and 260 VAC) |
0.99 min (between 90 VAC and 260 VAC) |
Output Requirements
100 W Supply
Parameter |
Details |
---|---|
Output Power |
100 W max (total for all three outputs) |
Output Voltages & Current |
+5 VDC: 4.875 to 5.25V (0-20 A) +12 VDC: 11.64 to 12.6V (0-2 A) -12 VDC: -12.6 to -11.64V (0-1 A) |
Overvoltage Limit |
+5 VDC: 5.7 to 6.7V |
Overcurrent Limit |
+5 VDC: 21 A (typical) +12 VDC: 2.5 A (typical) -12 VDC: 3.5 A (typical) |
350 W Supply
Parameter |
Details |
---|---|
Output Power |
350 W max (total for all three outputs) |
Output Voltages & Current |
+5 VDC: 4.875 to 5.25V (0-60 A) +12 VDC: 11.64 to 12.6V (0-12 A) -12 VDC: -12.6 to -11.64V (0-4 A) |
Overvoltage Limit |
+5 VDC: 5.7 to 6.7V |
Overcurrent Limit |
+5 VDC: 66 A (typical) +12 VDC: 15 A (typical) -12 VDC: 4.6 A (typical) |
Isolation & Protective Limits
Parameter |
Details |
---|---|
Isolation (Input to Outputs) |
250 VAC continuous; 1500 VAC for 1 min |
Ride-Through (AC Loss Tolerance) |
15 ms min |
Hold-Up Time (AC Failure Signal to DC Drop) |
5 ms min |
Operating Temperature
Supply Type |
Temperature Range |
---|---|
100W Supply |
0°C to 60°C (32°F to 140°F) |
350W Supply |
0°C to 60°C (32°F to 140°F) (Fan tray required for full capacity) |