Product Details: Bently Nevada 9200-02-05-10-00 Two-wire Seismoprobe Transducer


General Information

  • Manufacturer: Bently Nevada
  • Model/Part Number: 9200-02-05-10-00
  • Description:
    • A two-wire transducer designed for seismic vibration measurement.
    • It features high accuracy and durability with an optional fluid-resistant cable.
    • Provides output related to the vibration of the machine or casing, which can be used with 3300 or 3500 monitors.

Specifications

Parameter Details
Electrical Sensitivity 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration
Calibration Load 10 kΩ Terminal "A" to "B" Output
Sensitivity Temperature Coefficient 0.2%/°C
Frequency Response 4.5 to 1000 Hz (270 to 60,000 CPM), +0, -3dB typical
Dynamic Operating Range 2.54 mm (0.100 in) peak to peak maximum displacement
Velocity Range 25 mm/s (1 in/s) at +22°C with a 10 kΩ load
Coil Resistance 1.25 kΩ ±5%
Locked Coil Inductance 125 mH, typical
Amplitude Linearity ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000 CPM)
Shock Resistance Withstands 50 g peak maximum acceleration along non-sensitive axis
Transverse Sensitivity ±10% maximum of sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s)
Polarity of Output Signal Pin A goes positive with respect to Pin B when transducer case velocity is towards the connector
Lead Wire Length 305 meters (1,000 feet) maximum, consult manual for frequency roll-off at longer lengths

Environmental Limits

Parameter Operating Temperature Storage Temperature
9200 Series -29°C to +121°C (-20°F to +250°F) -29°C to +121°C (-20°F to +250°F)
74712 Series (Alternative) -29°C to +204°C (-20°F to +400°F) -29°C to +204°C (-20°F to +400°F)
Humidity 95% relative humidity, non-condensing.
100% non-submerged with integral cable option

Mounting and Connector Options

  • A: Transducer Mounting Angle/Minimum Operating Frequency Option

    • 01: 0 ±2.5°, 4.5 Hz (270 cpm)
    • 02: 45 ±2.5°, 4.5 Hz (270 cpm)
    • 03: 90 ±2.5°, 4.5 Hz (270 cpm)
    • 06: 0 ±100°, 10 Hz (600 cpm)
    • 09: 0 ±180°, 15 Hz (900 cpm)
  • B: Connector/Cable Option

    • 01: Top Mount (no cable)
    • 02: Side Mount (no cable)
    • 05: Terminal block top mount (no cable)
    • 10-50: Integral hardline cable options (7 to 50 feet)
  • C: Mounting Base Option

    • 01: Circular, 1/4-20 UNC stud
    • 02: Circular, 1/4-28 UNF stud
    • 03: Rectangular flange
    • 04: Circular, with three 8-32 threaded studs (44 mm bolt circle)
    • Multiple isolated base and stud configurations available.
  • D: Agency Approval Option

    • 00: No Approvals
    • 01: CSA
    • 04: ATEX/IECEx

Physical Dimensions and Weight

Parameter Details
Height 102 mm (4 in) typical
Diameter 41 mm (1.6 in) typical
Weight 9200 = 300 g (10.5 oz) typical, 74712 = 480 g (17 oz) typical

Notes

  • For optimal performance, the mounting angle and minimum operating frequency should match your specific application needs.
  • Ensure proper cable selection based on environmental conditions, especially when operating in hazardous or extreme environments.
  • The output signal polarity depends on the transducer case velocity direction relative to the connector.
View full details

Product Description

Product Details: Bently Nevada 9200-02-05-10-00 Two-wire Seismoprobe Transducer


General Information

  • Manufacturer: Bently Nevada
  • Model/Part Number: 9200-02-05-10-00
  • Description:
    • A two-wire transducer designed for seismic vibration measurement.
    • It features high accuracy and durability with an optional fluid-resistant cable.
    • Provides output related to the vibration of the machine or casing, which can be used with 3300 or 3500 monitors.

Specifications

Parameter Details
Electrical Sensitivity 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration
Calibration Load 10 kΩ Terminal "A" to "B" Output
Sensitivity Temperature Coefficient 0.2%/°C
Frequency Response 4.5 to 1000 Hz (270 to 60,000 CPM), +0, -3dB typical
Dynamic Operating Range 2.54 mm (0.100 in) peak to peak maximum displacement
Velocity Range 25 mm/s (1 in/s) at +22°C with a 10 kΩ load
Coil Resistance 1.25 kΩ ±5%
Locked Coil Inductance 125 mH, typical
Amplitude Linearity ±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000 CPM)
Shock Resistance Withstands 50 g peak maximum acceleration along non-sensitive axis
Transverse Sensitivity ±10% maximum of sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s)
Polarity of Output Signal Pin A goes positive with respect to Pin B when transducer case velocity is towards the connector
Lead Wire Length 305 meters (1,000 feet) maximum, consult manual for frequency roll-off at longer lengths

Environmental Limits

Parameter Operating Temperature Storage Temperature
9200 Series -29°C to +121°C (-20°F to +250°F) -29°C to +121°C (-20°F to +250°F)
74712 Series (Alternative) -29°C to +204°C (-20°F to +400°F) -29°C to +204°C (-20°F to +400°F)
Humidity 95% relative humidity, non-condensing.
100% non-submerged with integral cable option

Mounting and Connector Options

  • A: Transducer Mounting Angle/Minimum Operating Frequency Option

    • 01: 0 ±2.5°, 4.5 Hz (270 cpm)
    • 02: 45 ±2.5°, 4.5 Hz (270 cpm)
    • 03: 90 ±2.5°, 4.5 Hz (270 cpm)
    • 06: 0 ±100°, 10 Hz (600 cpm)
    • 09: 0 ±180°, 15 Hz (900 cpm)
  • B: Connector/Cable Option

    • 01: Top Mount (no cable)
    • 02: Side Mount (no cable)
    • 05: Terminal block top mount (no cable)
    • 10-50: Integral hardline cable options (7 to 50 feet)
  • C: Mounting Base Option

    • 01: Circular, 1/4-20 UNC stud
    • 02: Circular, 1/4-28 UNF stud
    • 03: Rectangular flange
    • 04: Circular, with three 8-32 threaded studs (44 mm bolt circle)
    • Multiple isolated base and stud configurations available.
  • D: Agency Approval Option

    • 00: No Approvals
    • 01: CSA
    • 04: ATEX/IECEx

Physical Dimensions and Weight

Parameter Details
Height 102 mm (4 in) typical
Diameter 41 mm (1.6 in) typical
Weight 9200 = 300 g (10.5 oz) typical, 74712 = 480 g (17 oz) typical

Notes

  • For optimal performance, the mounting angle and minimum operating frequency should match your specific application needs.
  • Ensure proper cable selection based on environmental conditions, especially when operating in hazardous or extreme environments.
  • The output signal polarity depends on the transducer case velocity direction relative to the connector.