The 3500/62 Process Variable Monitor is a 6-channel module designed for monitoring machine-critical parameters, such as:

  • Pressures
  • Flows
  • Temperatures
  • Levels

Key Features:

  • Accepts +4 to +20 mA current inputs or proportional voltage inputs ranging from -10 Vdc to +10 Vdc.
  • Configurable via the 3500 Rack Configuration Software for current or voltage measurement.
  • Offers alarm setpoint programming to compare processed signals against user-defined thresholds.

Input Options:

  1. +/-10 Volts DC
  2. Isolated 4-20 mA
  3. 4-20 mA with Intrinsically Safe Zener Barriers
  • The Internal Barrier I/O includes external power input terminals for providing intrinsically safe power to 4-20 mA transducers.

Redundancy Configuration:

  • In Triple Modular Redundant (TMR) setups:
    • Install monitors in groups of three, adjacent to one another.
    • Utilizes voting mechanisms to ensure:
      • Accurate operation.
      • Protection against single-point failures.
View full details

Product Description

Product Details

  • Manufacturer: Bently Nevada
  • Model/Part Number: 163179-03
  • Description: 3500/62 Process Variable Monitor

Description

The 3500/62 Process Variable Monitor is a 6-channel module designed for monitoring machine-critical parameters, such as:

  • Pressures
  • Flows
  • Temperatures
  • Levels

Key Features:

  • Accepts +4 to +20 mA current inputs or proportional voltage inputs ranging from -10 Vdc to +10 Vdc.
  • Configurable via the 3500 Rack Configuration Software for current or voltage measurement.
  • Offers alarm setpoint programming to compare processed signals against user-defined thresholds.

Input Options:

  1. +/-10 Volts DC
  2. Isolated 4-20 mA
  3. 4-20 mA with Intrinsically Safe Zener Barriers
  • The Internal Barrier I/O includes external power input terminals for providing intrinsically safe power to 4-20 mA transducers.

Redundancy Configuration:

  • In Triple Modular Redundant (TMR) setups:
    • Install monitors in groups of three, adjacent to one another.
    • Utilizes voting mechanisms to ensure:
      • Accurate operation.