Product Description
Product Details
- Manufacturer: Bently Nevada
- Series: 3500/50
- Model/Part Number: 3500/50-01-00-01, 133388-02, 133442-01
- Model Type: Tachometer Module
Description
The 3500/50M Tachometer Module is a 2-channel module designed to measure shaft rotational speed, rotor acceleration, and rotor direction. It accepts input from proximity probes or magnetic pickups and compares these measurements against user-programmable alarm setpoints. The module generates alarms when the setpoints are violated, ensuring continuous monitoring of critical machine parameters.
Specifications
-
Inputs:
- Signal: Accepts up to 2 transducer signals from proximity probes or magnetic pickups.
- Input Signal Range: +10.0 V to -24.0 V (signals exceeding this range are limited internally by the module).
-
Input Impedance:
- Standard: 20 kΩ
- TMR: 40 kΩ
- Internal Barrier: 7.15 kΩ
- Transducers: 1 to 2 proximity transducer signals; restrictions apply to magnetic pickups.
-
Speed Input:
- Supports 1 to 255 events per revolution for rotor acceleration and zero-speed channel types.
- All other channel types support a range of 0.0039 to 255 events per revolution.
- Maximum Full Scale: 99,999 rpm, with a maximum input frequency of 20 kHz.
-
Minimum Input Frequency:
- Proximity transducers: 0.0167 Hz (1 rpm for 1 event per revolution).
- Passive magnetic pickups: 3.3 Hz.
-
Power Consumption: 5.8 Watts, typical.
Physical Specifications
-
Monitor Module (Main Board):
- Dimensions: 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
- Weight: 0.82 kg (1.8 lb)
-
I/O Modules (non-barrier):
- Dimensions: 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
- Weight: 0.20 kg (0.44 lb)
-
I/O Modules (internal barrier):
- Dimensions: 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)
- Weight: 0.46 kg (1.01 lb)
Ordering Information
-
3500/50M Tachometer Module:
- 3500/50-AA-BB
- 01: I/O Module with Internal Terminations
- 02: I/O Module with External Terminations
- 04: I/O Module with Internal Barriers and Internal Terminations
- 00: None
- 01: cNRTLus (Class 1, Division 2)
- 02: ATEX/IECEx/CSA (Class 1, Zone 2)