Product Description
Product Details
Manufacturer | Bently Nevada |
---|---|
Series | 3500/40M |
Model/Part Number | 140734-01 |
Model Type | Proximitor Monitor |
Description
The 3500/40M Proximitor Monitor is a four-channel monitor that accepts input from Bently Nevada proximity transducers. It conditions the signals to provide various vibration and position measurements, and compares the conditioned signals with user-programmable alarms. Users can program each channel using the 3500 Rack Configuration Software to perform the following functions:
- Radial vibration
- Eccentricity
- REBAM (Rotating Equipment Balance Measurement)
- Thrust position
- Differential expansion
Specifications
Power Consumption:
- 7.7 Watts (typical)
Input Signals:
- Accepts from 1 to 4 proximity transducer signals.
Input Impedance:
- Standard I/O: 10 kΩ (Proximitor and acceleration inputs)
Sensitivity:
- Radial Vibration: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil)
- Thrust: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil)
- Eccentricity: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil)
- Differential Expansion: 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil)
- REBAM: 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil)
Outputs:
-
Front Panel LEDs:
- OK LED: Indicates normal operation.
- TX/RX LED: Indicates communication status.
- Bypass LED: Indicates when the module is in Bypass Mode.
-
Buffered Transducer Outputs:
- One coaxial connector per channel, with short-circuit protection.
- Output Impedance: 550 Ω
Transducer Power Supply:
- -24 Vdc
Environmental Limits
Operating Temperature:
- Non-Barrier I/O Module: -30°C to +65°C (-22°F to +150°F)
- Internal Barrier I/O Module: 0°C to +65°C (32°F to +150°F)
Storage Temperature:
- -40°C to +85°C (-40°F to +185°F)
Humidity:
- 95%, non-condensing
Physical Dimensions
Dimension | Value |
---|---|
Height | 241.3 mm (9.50 in) |
Width | 24.4 mm (0.96 in) |
Depth | 241.8 mm (9.52 in) |
Weight | 0.91 kg (2.0 lb) |
Ordering Information
Code | Description |
---|---|
A | I/O Module Type |
01 | Proximitor I/O Module with Internal Termination |
02 | Proximitor I/O Module with External Terminations |
03 | Proximitor I/O Module with Internal Barriers and Internal Terminations |
| B | Hazardous Area Approval Option | | 00 | None | | 01 | cNRTLus (Class 1, Division 2) | | 02 | ATEX / IECEx / CSA (Class 1, Zone 2) |