Skip to product information
1 of 3

Allen-Bradley 2094-BC01-MP5-S IAM (460V) Modules Power

Allen-Bradley 2094-BC01-MP5-S IAM (460V) Modules Power

  • Manufacturer: Allen-Bradley

  • Product No.: 2094-BC01-MP5-S

  • Condition:1000 in stock

  • Product Type: IAM (460V) Modules Power

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 10000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Details

Manufacturer: Allen-Bradley
Model/Part Number: 2094-BC01-MP5-S
Description: IAM (460V) Modules Power

Specifications

Parameter Value
AC Input Voltage 324…528V rms (three-phase), 360…480V nominal
AC Input Frequency 47…63 Hz
Main AC Input Current Nominal: 10 A (rms), Max Inrush: 10 A (0-pk)
DC Input Voltage (Common Bus Follower) 458…747V dc
DC Input Current (Common Bus Follower) 10 A
Control Power AC Input Voltage 95…264V rms (single-phase), 230V nominal
Control Power AC Input Current Nominal (@ 220/230V): 3 A (rms), Nominal (@ 110/115V): 6 A (rms), Max Inrush: 25 A
Nominal Bus Output Voltage 650V dc
Line Loss Ride Through 20 ms
Continuous Output Current to Bus 10 A
Intermittent Output Current to Bus 20 A
Bus Overvoltage 825V dc
Bus Undervoltage 275V dc
Internal Shunt Continuous Power: 50 W, Peak Power: 5600 W
Internal Shunt Resistor 115 Ω
Shunt On 805V dc
Shunt Off 755V dc
Continuous Power Output to Bus 6 kW
Peak Power Output 12 kW
Efficiency 95%
Converter Inductance 250 μH
Converter Capacitance 110 μF

Power Dissipation Specifications

Kinetix 6000 Drive Module 20% Usage (watts) 40% Usage (watts) 60% Usage (watts) 80% Usage (watts) 100% Usage (watts)
Power Dissipation 15 20 25 30 35
View full details

Product Description

Product Details

Manufacturer: Allen-Bradley
Model/Part Number: 2094-BC01-MP5-S
Description: IAM (460V) Modules Power

Specifications

Parameter Value
AC Input Voltage 324…528V rms (three-phase), 360…480V nominal
AC Input Frequency 47…63 Hz
Main AC Input Current Nominal: 10 A (rms), Max Inrush: 10 A (0-pk)
DC Input Voltage (Common Bus Follower) 458…747V dc
DC Input Current (Common Bus Follower) 10 A
Control Power AC Input Voltage 95…264V rms (single-phase), 230V nominal
Control Power AC Input Current Nominal (@ 220/230V): 3 A (rms), Nominal (@ 110/115V): 6 A (rms), Max Inrush: 25 A
Nominal Bus Output Voltage 650V dc
Line Loss Ride Through 20 ms
Continuous Output Current to Bus 10 A
Intermittent Output Current to Bus 20 A
Bus Overvoltage 825V dc
Bus Undervoltage 275V dc
Internal Shunt Continuous Power: 50 W, Peak Power: 5600 W
Internal Shunt Resistor 115 Ω
Shunt On 805V dc
Shunt Off 755V dc
Continuous Power Output to Bus 6 kW
Peak Power Output 12 kW
Efficiency 95%
Converter Inductance 250 μH
Converter Capacitance 110 μF

Power Dissipation Specifications

Kinetix 6000 Drive Module 20% Usage (watts) 40% Usage (watts) 60% Usage (watts) 80% Usage (watts) 100% Usage (watts)
Power Dissipation 15 20 25 30 35

Download PDF file here: