Allen-Bradley 1769-IF4 CompactLogix 4 Pt A/I C and V Module

Allen-Bradley 1769-IF4 CompactLogix 4 Pt A/I C and V Module

  • Manufacturer: Allen-Bradley

  • Product No.: 1769-IF4

  • Condition:1000 in stock

  • Product Type: CompactLogix 4 Pt A/I C and V Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Allen-Bradley 1769-IF4 CompactLogix 4 Pt A/I C and V Module

Manufacturer: Allen-Bradley
Model/Part Number: 1769-IF4
Description: CompactLogix 4 Pt A/I C and V Module


General Specifications

Attribute Specification
Dimensions 118 mm (height) x 87 mm (depth) x 35 mm (width); height including mounting tabs is 138 mm
Approximate Shipping Weight 300g (0.65 lbs.)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Operating Temperature 0°C to +60°C (32°F to +140°F)
Operating Humidity 5% to 95% non-condensing
Operating Altitude 2000 meters (6561 feet)
Vibration Operating: 10 to 500 Hz, 5G, 0.030 in. peak-to-peak
Shock (Operating) 30G, 11 ms (panel mounted), 20G, 11 ms (DIN rail mounted)
Shock (Relay Operation) 7.5G panel mounted, 5G DIN rail mounted
Shock (Non-Operating) 40G panel mounted, 30G DIN rail mounted
Agency Certifications • C-UL certified (CSA C22.2 No. 142)
• UL 508 listed
• CE compliant
Hazardous Environment Class Class I, Division 2, Hazardous Location, Groups A, B, C, D
Radiated and Conducted Emissions EN50081-2 Class A
Electrical/EMC Immunity • ESD Immunity (IEC1000-4-2) 4kV contact, 8kV air
• Radiated Immunity (IEC1000-4-3) 10V/m, 80 to 1000 MHz
• Surge Immunity (IEC1000-4-5) 1kV galvanic gun

Input Specifications

Attribute Specification
Analog Operating Ranges Voltage: ±10V dc, 0 to 10V dc, 0 to 5V dc, 1 to 5V dc
Current: 0 to 20 mA, 4 to 20 mA
Full Scale Analog Ranges Voltage: ±10.5V dc, -0.5 to 10.5V dc, -0.5 to 5.25V dc, 0.5 to 5.25V dc
Current: 0 to 21 mA, 3.2 to 21 mA
Number of Inputs 4 differential or single-ended
Bus Current Draw (max.) 120 mA at 5V dc, 60 mA at 24V dc (if using optional 24V dc Class 2 power supply, current draw is 0 mA)
Heat Dissipation 2.52 Total Watts
Converter Type Delta Sigma
Resolution 14 bits (unipolar), 14 bits plus sign (bipolar)
Rated Working Voltage 30V ac / 30V dc
Common Mode Voltage Range ±10V dc maximum per channel
Common Mode Rejection >60 dB at 50 and 60 Hz with 50 or 60 Hz filter
Normal Mode Rejection Ratio -50 dB at 50 and 60 Hz with 50 or 60 Hz filter
Input Impedance Voltage Terminal: 220KΩ (typical), Current Terminal: 250Ω
Accuracy Voltage Terminal: ±0.2% full scale at 25°C
Current Terminal: ±0.35% full scale at 25°C
Accuracy Drift with Temperature Voltage Terminal: ±0.003% per °C
Current Terminal: ±0.0045% per °C
Repeatability ±0.03%
Module Error over Full Temperature Range Voltage: ±0.3%
Current: ±0.5%
Optional 24V dc Power Supply Voltage Range 20.4V to 26.4V dc
Calibration Autocalibration on channel enable and on configuration change
Maximum Overload at Input Terminals Voltage Terminal: ±30V dc continuous, Current Terminal: ±32 mA continuous

Module Diagnostics and Configuration

  • Module OK LED: On indicates the module has power, passed internal diagnostics, and is communicating. Off indicates any of the conditions are not met.
  • Channel Diagnostics: Over- or under-range indicated by bit reporting.
  • Input Channel Configuration: Via configuration software or user program by writing a unique bit pattern into the module’s configuration file.
  • System Power Supply Distance Rating: The module may not be more than 8 modules away from the system power supply.

Certifications and Compliance

  • C-UL: Certified under CSA C22.2 No. 142
  • UL 508: Listed
  • CE: Compliant for all applicable directives
  • Hazardous Location: Class I, Division 2, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)

Recommended Cable

  • Belden™ 8761 (shielded)

This module provides high-performance analog inputs with a range of voltage and current input options, ideal for CompactLogix systems. It is designed for harsh industrial environments, supporting certifications and compliance for hazardous locations and ensuring strong electrical and EMC immunity.

View full details

Product Description

Allen-Bradley 1769-IF4 CompactLogix 4 Pt A/I C and V Module

Manufacturer: Allen-Bradley
Model/Part Number: 1769-IF4
Description: CompactLogix 4 Pt A/I C and V Module


General Specifications

Attribute Specification
Dimensions 118 mm (height) x 87 mm (depth) x 35 mm (width); height including mounting tabs is 138 mm
Approximate Shipping Weight 300g (0.65 lbs.)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Operating Temperature 0°C to +60°C (32°F to +140°F)
Operating Humidity 5% to 95% non-condensing
Operating Altitude 2000 meters (6561 feet)
Vibration Operating: 10 to 500 Hz, 5G, 0.030 in. peak-to-peak
Shock (Operating) 30G, 11 ms (panel mounted), 20G, 11 ms (DIN rail mounted)
Shock (Relay Operation) 7.5G panel mounted, 5G DIN rail mounted
Shock (Non-Operating) 40G panel mounted, 30G DIN rail mounted
Agency Certifications • C-UL certified (CSA C22.2 No. 142)
• UL 508 listed
• CE compliant
Hazardous Environment Class Class I, Division 2, Hazardous Location, Groups A, B, C, D
Radiated and Conducted Emissions EN50081-2 Class A
Electrical/EMC Immunity • ESD Immunity (IEC1000-4-2) 4kV contact, 8kV air
• Radiated Immunity (IEC1000-4-3) 10V/m, 80 to 1000 MHz
• Surge Immunity (IEC1000-4-5) 1kV galvanic gun

Input Specifications

Attribute Specification
Analog Operating Ranges Voltage: ±10V dc, 0 to 10V dc, 0 to 5V dc, 1 to 5V dc
Current: 0 to 20 mA, 4 to 20 mA
Full Scale Analog Ranges Voltage: ±10.5V dc, -0.5 to 10.5V dc, -0.5 to 5.25V dc, 0.5 to 5.25V dc
Current: 0 to 21 mA, 3.2 to 21 mA
Number of Inputs 4 differential or single-ended
Bus Current Draw (max.) 120 mA at 5V dc, 60 mA at 24V dc (if using optional 24V dc Class 2 power supply, current draw is 0 mA)
Heat Dissipation 2.52 Total Watts
Converter Type Delta Sigma
Resolution 14 bits (unipolar), 14 bits plus sign (bipolar)
Rated Working Voltage 30V ac / 30V dc
Common Mode Voltage Range ±10V dc maximum per channel
Common Mode Rejection >60 dB at 50 and 60 Hz with 50 or 60 Hz filter
Normal Mode Rejection Ratio -50 dB at 50 and 60 Hz with 50 or 60 Hz filter
Input Impedance Voltage Terminal: 220KΩ (typical), Current Terminal: 250Ω
Accuracy Voltage Terminal: ±0.2% full scale at 25°C
Current Terminal: ±0.35% full scale at 25°C
Accuracy Drift with Temperature Voltage Terminal: ±0.003% per °C
Current Terminal: ±0.0045% per °C
Repeatability ±0.03%
Module Error over Full Temperature Range Voltage: ±0.3%
Current: ±0.5%
Optional 24V dc Power Supply Voltage Range 20.4V to 26.4V dc
Calibration Autocalibration on channel enable and on configuration change
Maximum Overload at Input Terminals Voltage Terminal: ±30V dc continuous, Current Terminal: ±32 mA continuous

Module Diagnostics and Configuration

  • Module OK LED: On indicates the module has power, passed internal diagnostics, and is communicating. Off indicates any of the conditions are not met.
  • Channel Diagnostics: Over- or under-range indicated by bit reporting.
  • Input Channel Configuration: Via configuration software or user program by writing a unique bit pattern into the module’s configuration file.
  • System Power Supply Distance Rating: The module may not be more than 8 modules away from the system power supply.

Certifications and Compliance

  • C-UL: Certified under CSA C22.2 No. 142
  • UL 508: Listed
  • CE: Compliant for all applicable directives
  • Hazardous Location: Class I, Division 2, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)

Recommended Cable

  • Belden™ 8761 (shielded)

This module provides high-performance analog inputs with a range of voltage and current input options, ideal for CompactLogix systems. It is designed for harsh industrial environments, supporting certifications and compliance for hazardous locations and ensuring strong electrical and EMC immunity.

Download PDF file here:

Click to Download PDF