Skip to product information
NaN of -Infinity

ALLEN BRADLEY 1746-P2/C Power Supply Module for SLC 500 PLCs

ALLEN BRADLEY 1746-P2/C Power Supply Module for SLC 500 PLCs

  • Manufacturer: ALLEN BRADLEY

  • Product No.: 1746-P2/C

  • Condition:1000 in stock

  • Product Type: Power Supply Module for SLC 500 PLCs

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

🔹 General Information

Manufacturer

Allen-Bradley

Model/Part Number

1746-P2/C

Description

Power Supply Module for SLC 500 PLCs

Product Series

SLC 500


 



🔹 Power Supply Specifications

Attribute

Specification

Line Voltage

85-132/170-265V AC, 47-63 Hz

Typical Line Power Requirement

180 VA

Maximum Inrush Current

45A

Internal Current Capacity

0.46A at 24V DC, 2A at 5V DC

Fuse Protection

1746-F2 or equivalent (Fuse is soldered in place)

24V DC User Power Current Capacity

1A

24V DC User Power Voltage Range

20.4-27.6V DC

Max. User-Supplied Overcurrent Protection

15A

Ambient Operating Temperature

0°C to +60°C (+32°F to +140°F)

Isolation

2600V DC for 1s

CPU Hold-up Time

5 ms (full load), 1000 ms (no load)


 



🔹 Certifications

Certification

UL Listed Industrial Control Equipment for Class 1, Division 2, Groups A, B, C, D Hazardous Locations

CSA Certified Process Control Equipment for Class 1, Div 2, Groups A, B, C, D Hazardous Locations

CE, European Union 89/336/EEC EMC Directive

C-Tick, Australian Radio Communications Act

 

View full details

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Product Description

🔹 General Information

Manufacturer

Allen-Bradley

Model/Part Number

1746-P2/C

Description

Power Supply Module for SLC 500 PLCs

Product Series

SLC 500


 



🔹 Power Supply Specifications

Attribute

Specification

Line Voltage

85-132/170-265V AC, 47-63 Hz

Typical Line Power Requirement

180 VA

Maximum Inrush Current

45A

Internal Current Capacity

0.46A at 24V DC, 2A at 5V DC

Fuse Protection

1746-F2 or equivalent (Fuse is soldered in place)

24V DC User Power Current Capacity

1A

24V DC User Power Voltage Range

20.4-27.6V DC

Max. User-Supplied Overcurrent Protection

15A

Ambient Operating Temperature

0°C to +60°C (+32°F to +140°F)

Isolation

2600V DC for 1s

CPU Hold-up Time

5 ms (full load), 1000 ms (no load)


 



🔹 Certifications

Certification

UL Listed Industrial Control Equipment for Class 1, Division 2, Groups A, B, C, D Hazardous Locations

CSA Certified Process Control Equipment for Class 1, Div 2, Groups A, B, C, D Hazardous Locations

CE, European Union 89/336/EEC EMC Directive

C-Tick, Australian Radio Communications Act

 

Download PDF file here:

Click to Download PDF