🔹 General Information

Manufacturer

Allen-Bradley

Model/Part Number

1734-TB

Description

POINT I/O Terminal Base


 



🔹 Technical Specifications

Attribute

Specification

Field Power Bus - Supply Voltage (Max)

28.8V DC, 120/240V AC

Field Power Bus - Supply Current (Max)

10 A

Signal Terminal Voltage

28.8V DC, 120V/240V AC

Signal Terminal Current

2 A

Enclosure Type Rating

None (open-style)

Terminal Base Screw Torque

0.8 N•m (7 lb•in)

Wire Size (Without End Ferrule)

0.25…2.5 mm² (22…14 AWG) solid or stranded shielded copper wire, rated at 75°C (167°F) or greater, 1.2 mm (3/64 in.) insulation max

Wire Size (With End Ferrule)

0.75 mm² (18 AWG)


 



🔹 Environmental Specifications

Attribute

Specification

Operating Temperature

-20°C to +55°C (-4°F to +131°F)

Surrounding Air Temperature (Max)

55°C (131°F)

Non-Operating Temperature

-40°C to +85°C (-40°F to +185°F)

Relative Humidity

5…95% non-condensing

Vibration

5 g @ 10…500 Hz

Shock (Operating)

30 g

Shock (Non-Operating)

50 g

Emissions Compliance

IEC 61000-6-4

ESD Immunity

IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges

Radiated RF Immunity

IEC 61000-4-3: 10V/m (80…2700 MHz)

EFT/B Immunity

IEC 61000-4-4: ±2 kV at 5 kHz on power and signal ports

Surge Transient Immunity

IEC 61000-4-5: ±1 kV line-line (DM), ±2 kV line-earth (CM) on signal ports

Conducted RF Immunity

IEC 61000-4-6: 10V rms (150 kHz…80 MHz)


 

View full details

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Product Description

🔹 General Information

Manufacturer

Allen-Bradley

Model/Part Number

1734-TB

Description

POINT I/O Terminal Base


 



🔹 Technical Specifications

Attribute

Specification

Field Power Bus - Supply Voltage (Max)

28.8V DC, 120/240V AC

Field Power Bus - Supply Current (Max)

10 A

Signal Terminal Voltage

28.8V DC, 120V/240V AC

Signal Terminal Current

2 A

Enclosure Type Rating

None (open-style)

Terminal Base Screw Torque

0.8 N•m (7 lb•in)

Wire Size (Without End Ferrule)

0.25…2.5 mm² (22…14 AWG) solid or stranded shielded copper wire, rated at 75°C (167°F) or greater, 1.2 mm (3/64 in.) insulation max

Wire Size (With End Ferrule)

0.75 mm² (18 AWG)


 



🔹 Environmental Specifications

Attribute

Specification

Operating Temperature

-20°C to +55°C (-4°F to +131°F)

Surrounding Air Temperature (Max)

55°C (131°F)

Non-Operating Temperature

-40°C to +85°C (-40°F to +185°F)

Relative Humidity

5…95% non-condensing

Vibration

5 g @ 10…500 Hz

Shock (Operating)

30 g

Shock (Non-Operating)

50 g

Emissions Compliance

IEC 61000-6-4

ESD Immunity

IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges

Radiated RF Immunity

IEC 61000-4-3: 10V/m (80…2700 MHz)

EFT/B Immunity

IEC 61000-4-4: ±2 kV at 5 kHz on power and signal ports

Surge Transient Immunity

IEC 61000-4-5: ±1 kV line-line (DM), ±2 kV line-earth (CM) on signal ports

Conducted RF Immunity

IEC 61000-4-6: 10V rms (150 kHz…80 MHz)


 

Download PDF file here: