Skip to product information
1 of 3

A6110 Emerson Machinery Health Monitor

A6110 Emerson Machinery Health Monitor

  • Manufacturer: EMERSON

  • Product No.: A6110

  • Condition:1000 in stock

  • Product Type: Machinery Health Monitor

  • Product Origin: United States

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Product Details

Manufacturer: Emerson
Model/Part Number: A6110
Description: Shaft Relative Vibration Monitor for AMS 6500 Machinery Health Monitor

Transducer Inputs

Parameter Specification
Number of Inputs Two, independent or combined monitoring modes
Type of Inputs Eddy current, differential
Emerson Sensor Inputs Part numbers: 6422, 6423, 6424, 6425
Isolation Galvanically separated from power supply
Input Resistance >100 kΩ
Input Voltage Range 0 to -22 VDC
Input Frequency Range Lower cutoff: 1 or 5 Hz
Upper cutoff: 50 - 2000 Hz (adjustable)

Measuring Range

  • Range: Continuously adjustable via configuration software
  • Smallest Range: 0 - 400 mV
  • Largest Range: 0 - 8000 mV

Dimensions

Parameter Specification
Format PCB/EURO card format: DIN 41494, 100 x 160 mm (3.937 x 6.300 in)
Width 30.0 mm (1.181 in) (6 TE)
Height 128.4 mm (5.055 in) (3 HE)
Length 160.0 mm (6.300 in)
Net Weight Approx. 320 g (0.705 lbs)
Gross Weight Approx. 450 g (0.992 lbs) (including standard packing)
Packing Volume Approx. 2.5 dm³ (0.08 ft³)

Space Requirements

  • Requires 1 slot
  • 14 modules fit into each 19” rack
View full details

Product Description

Product Details

Manufacturer: Emerson
Model/Part Number: A6110
Description: Shaft Relative Vibration Monitor for AMS 6500 Machinery Health Monitor

Transducer Inputs

Parameter Specification
Number of Inputs Two, independent or combined monitoring modes
Type of Inputs Eddy current, differential
Emerson Sensor Inputs Part numbers: 6422, 6423, 6424, 6425
Isolation Galvanically separated from power supply
Input Resistance >100 kΩ
Input Voltage Range 0 to -22 VDC
Input Frequency Range Lower cutoff: 1 or 5 Hz
Upper cutoff: 50 - 2000 Hz (adjustable)

Measuring Range

  • Range: Continuously adjustable via configuration software
  • Smallest Range: 0 - 400 mV
  • Largest Range: 0 - 8000 mV

Dimensions

Parameter Specification
Format PCB/EURO card format: DIN 41494, 100 x 160 mm (3.937 x 6.300 in)
Width 30.0 mm (1.181 in) (6 TE)
Height 128.4 mm (5.055 in) (3 HE)
Length 160.0 mm (6.300 in)
Net Weight Approx. 320 g (0.705 lbs)
Gross Weight Approx. 450 g (0.992 lbs) (including standard packing)
Packing Volume Approx. 2.5 dm³ (0.08 ft³)

Space Requirements

  • Requires 1 slot
  • 14 modules fit into each 19” rack

Download PDF file here:

Click to Download PDF