Skip to product information
1 of 5

1SFL491001R8011 | ABB Contactor

1SFL491001R8011 | ABB Contactor

  • Manufacturer: ABB

  • Product No.: 1SFL491001R8011

  • Condition:1000 in stock

  • Product Type: Contactors

  • Product Origin: Sweden

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

General Information

  • Catalog No.: 1SFA611621R1042
  • Alternate Catalog No.: A185-30-11
  • Description: A185-30-11 220-230V 50Hz / 230-240V 60Hz Contactor
  • Invoice Description: A185-30-11 220-230V 50Hz / 230-240V 60Hz Contactor
  • Country of Origin: Sweden (SE) - Imported by ABB India Limited
  • HSN Number: 85364900
  • Total GST Percentage: 18.00%

Technical Specifications

Parameter Specification
Number of Main Contacts NO 3
Number of Aux Contacts NO 1
Number of Aux Contacts NC 1
Rated Operational Voltage 690 V (Main Circuit)
Rated Control Circuit Voltage (Uc) 50 Hz: 220-230V, 60 Hz: 230-240V
Rated Frequency (f) 50 / 60 Hz
Rated Frequency Limits 25 ... 400 Hz
Rated Operational Current AC-1 (Ie) (1000 V) 40°C: 200 A, (690 V) 55°C: 250 A
Rated Operational Current AC-3 (Ie) (1000 V) 55°C: 185 A, (440 V) 55°C: 185 A
Rated Operational Current DC-1 (Ie) (110 V) 40°C: 275 A, (220 V) 40°C: 275 A
Rated Operational Current DC-5 (Ie) (110 V) 40°C: 275 A, (220 V) 40°C: 275 A
Rated Operational Power AC-3 (Pe) (220 / 230 / 240 V) 55 kW, (690 V) 132 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Conventional Free-air Thermal Current (Ith) 275 A at 40°C
Max Mechanical Switching Frequency 3600 cycles per hour
Max Electrical Switching Frequency AC-1: 300 cycles/hour, AC-2 / AC-4: 150 cycles/hour, AC-3: 300 cycles/hour
Coil Consumption 50 Hz: 35 VA, 60 Hz: 40 VA (Holding)
Coil Pull-in Consumption 50 Hz: 550 VA, 60 Hz: 600 VA
Operate Time 5 ... 13 ms (NC Contact Closing)
Rated Insulation Voltage (Ui) UL/CSA: 600 V, IEC: 1000 V
Rated Short-time Withstand Current (Icw) 10 s: 1500 A, 1 min: 800 A
Full Load Amps (Motor Use) (440 ... 480 V AC) 156 A, (550 ... 600 V AC) 144 A
Ambient Air Temperature Storage: -40 to +70°C, Operating: -25 to +50°C with Thermal O/L Relay

Compatibility and Mounting

  • Compatibility: A Contactors
  • Mounted Aux Contacts: 1 NO, 1 NC
  • Terminal Type: Main Circuit: Bars

Environmental Information

  • Ambient Air Temperature (Storage): -40°C to +70°C
  • Ambient Air Temperature (Operating with Thermal O/L Relay): -25°C to +50°C
  • Ambient Air Temperature (Operating without Thermal O/L Relay): -40°C to +70°C

Package Information

Parameter Specification
Package Width 178 mm
Package Length 232 mm
Package Height 167 mm
Package Gross Weight 3.5 kg
View full details

Product Description

General Information

  • Catalog No.: 1SFA611621R1042
  • Alternate Catalog No.: A185-30-11
  • Description: A185-30-11 220-230V 50Hz / 230-240V 60Hz Contactor
  • Invoice Description: A185-30-11 220-230V 50Hz / 230-240V 60Hz Contactor
  • Country of Origin: Sweden (SE) - Imported by ABB India Limited
  • HSN Number: 85364900
  • Total GST Percentage: 18.00%

Technical Specifications

Parameter Specification
Number of Main Contacts NO 3
Number of Aux Contacts NO 1
Number of Aux Contacts NC 1
Rated Operational Voltage 690 V (Main Circuit)
Rated Control Circuit Voltage (Uc) 50 Hz: 220-230V, 60 Hz: 230-240V
Rated Frequency (f) 50 / 60 Hz
Rated Frequency Limits 25 ... 400 Hz
Rated Operational Current AC-1 (Ie) (1000 V) 40°C: 200 A, (690 V) 55°C: 250 A
Rated Operational Current AC-3 (Ie) (1000 V) 55°C: 185 A, (440 V) 55°C: 185 A
Rated Operational Current DC-1 (Ie) (110 V) 40°C: 275 A, (220 V) 40°C: 275 A
Rated Operational Current DC-5 (Ie) (110 V) 40°C: 275 A, (220 V) 40°C: 275 A
Rated Operational Power AC-3 (Pe) (220 / 230 / 240 V) 55 kW, (690 V) 132 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Conventional Free-air Thermal Current (Ith) 275 A at 40°C
Max Mechanical Switching Frequency 3600 cycles per hour
Max Electrical Switching Frequency AC-1: 300 cycles/hour, AC-2 / AC-4: 150 cycles/hour, AC-3: 300 cycles/hour
Coil Consumption 50 Hz: 35 VA, 60 Hz: 40 VA (Holding)
Coil Pull-in Consumption 50 Hz: 550 VA, 60 Hz: 600 VA
Operate Time 5 ... 13 ms (NC Contact Closing)
Rated Insulation Voltage (Ui) UL/CSA: 600 V, IEC: 1000 V
Rated Short-time Withstand Current (Icw) 10 s: 1500 A, 1 min: 800 A
Full Load Amps (Motor Use) (440 ... 480 V AC) 156 A, (550 ... 600 V AC) 144 A
Ambient Air Temperature Storage: -40 to +70°C, Operating: -25 to +50°C with Thermal O/L Relay

Compatibility and Mounting

  • Compatibility: A Contactors
  • Mounted Aux Contacts: 1 NO, 1 NC
  • Terminal Type: Main Circuit: Bars

Environmental Information

  • Ambient Air Temperature (Storage): -40°C to +70°C
  • Ambient Air Temperature (Operating with Thermal O/L Relay): -25°C to +50°C
  • Ambient Air Temperature (Operating without Thermal O/L Relay): -40°C to +70°C

Package Information

Parameter Specification
Package Width 178 mm
Package Length 232 mm
Package Height 167 mm
Package Gross Weight 3.5 kg

Tags: