Zu Produktinformationen springen
1 von 8

Triconex 3617E Digital Output Module

Triconex 3617E Digital Output Module

  • Manufacturer: Triconex

  • Product No.: 3617E

  • Condition:1000 auf Lager

  • Product Type: Digital Output Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

🔍 

Product Overview


Field

Details

Manufacturer

Triconex

Model/Part Number

3617E

Model Type

Digital Output Module (Supervised)

System Type

TMR (Triple Modular Redundant)

Nominal Voltage

48 VDC

Number of Outputs

8, commoned


 



 

⚙️

Technical Specifications – Triconex 3617E


Specification

Details

Voltage Range

36–72 VDC

Max Switching Power

150 W (resistive load)

Max Output Current per Point

1 A

Surge Current

5 A for 10 ms

Minimum Required Load

100 mA

ON-State Voltage Drop

< 2 V typical

Load Leakage Current

≤ 4 mA

Point Isolation

1500 VDC minimum

Secondary Power Supply

5.00 VDC ± 0.25 VDC

Frequency Range

Not applicable (DC module)

Fuses (Field Termination)

1 per output, 1.25 A fast-acting


 



 

💡

Diagnostics & Indicators


Indicator Type

Details

Channel Status

POINT, PWR, LOAD

Module Status LEDs

PASS, FAULT, ACTIVE


 



 

🎨

Additional Information


Attribute

Details

Color Code

Mint Green

Output Configuration

Commoned outputs


 

Vollständige Details anzeigen

Product Description

🔍 

Product Overview


Field

Details

Manufacturer

Triconex

Model/Part Number

3617E

Model Type

Digital Output Module (Supervised)

System Type

TMR (Triple Modular Redundant)

Nominal Voltage

48 VDC

Number of Outputs

8, commoned


 



 

⚙️

Technical Specifications – Triconex 3617E


Specification

Details

Voltage Range

36–72 VDC

Max Switching Power

150 W (resistive load)

Max Output Current per Point

1 A

Surge Current

5 A for 10 ms

Minimum Required Load

100 mA

ON-State Voltage Drop

< 2 V typical

Load Leakage Current

≤ 4 mA

Point Isolation

1500 VDC minimum

Secondary Power Supply

5.00 VDC ± 0.25 VDC

Frequency Range

Not applicable (DC module)

Fuses (Field Termination)

1 per output, 1.25 A fast-acting


 



 

💡

Diagnostics & Indicators


Indicator Type

Details

Channel Status

POINT, PWR, LOAD

Module Status LEDs

PASS, FAULT, ACTIVE


 



 

🎨

Additional Information


Attribute

Details

Color Code

Mint Green

Output Configuration

Commoned outputs


 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)