Zu Produktinformationen springen
1 von 7

Triconex 3601E 115 VAC Digital Output Module

Triconex 3601E 115 VAC Digital Output Module

  • Manufacturer: Triconex

  • Product No.: 3601E

  • Condition:1000 auf Lager

  • Product Type: 115 VAC Digital Output Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

🔍 

Product Overview


Field

Details

Manufacturer

Triconex

Model/Part Number

3601E

Description

115 VAC Digital Output Module

Type

TMR (Triple Modular Redundant)

Output Signals

16, non-commoned


 



 

⚙️

Technical Specifications – Triconex 3601E


Attribute

Specification

Nominal Voltage

115 VAC

Voltage Range

80–155 VAC

Frequency Range

47–63 Hz

Voltage Drop

< 3V (typical)

Max. Output Current

2 A per point

Surge Current Rating

12 A per cycle

Load Leakage Current

≤ 2 mA @ 60 Hz

Chassis Leakage Current

≤ 4 mA @ 60 Hz

Point Isolation Voltage

1500 VDC / 2500 VDC (3601T only)

Fuses (on Field Termination)

3 A fast-acting (1 per output)


 



 

🔎

Diagnostics & Indicators


Feature

Details

Status Indicators

ON/OFF state per point

Module Status LEDs

PASS, FAULT, ACTIVE

Field Alarm LEDs

LOAD/FUSE (per channel)


 



 

🎨

Additional Info


Attribute

Details

Color Code

Green

Output Configuration

Non-commoned

Module Category

AC Output Module


 

Vollständige Details anzeigen

Product Description

🔍 

Product Overview


Field

Details

Manufacturer

Triconex

Model/Part Number

3601E

Description

115 VAC Digital Output Module

Type

TMR (Triple Modular Redundant)

Output Signals

16, non-commoned


 



 

⚙️

Technical Specifications – Triconex 3601E


Attribute

Specification

Nominal Voltage

115 VAC

Voltage Range

80–155 VAC

Frequency Range

47–63 Hz

Voltage Drop

< 3V (typical)

Max. Output Current

2 A per point

Surge Current Rating

12 A per cycle

Load Leakage Current

≤ 2 mA @ 60 Hz

Chassis Leakage Current

≤ 4 mA @ 60 Hz

Point Isolation Voltage

1500 VDC / 2500 VDC (3601T only)

Fuses (on Field Termination)

3 A fast-acting (1 per output)


 



 

🔎

Diagnostics & Indicators


Feature

Details

Status Indicators

ON/OFF state per point

Module Status LEDs

PASS, FAULT, ACTIVE

Field Alarm LEDs

LOAD/FUSE (per channel)


 



 

🎨

Additional Info


Attribute

Details

Color Code

Green

Output Configuration

Non-commoned

Module Category

AC Output Module


 

Download PDF file here:

Click to Download PDF

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)