Honeywell FC-SDOL-0448 Safe Digital Output Module

Honeywell FC-SDOL-0448 Safe Digital Output Module

  • Manufacturer: Honeywell

  • Product No.: FC-SDOL-0448

  • Condition:1000 auf Lager

  • Product Type: Safe Digital Output Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

  • 24/7 Support
  • 30-Day Returns
  • Fast Shipping

Honeywell FC-SDOL-0448 Safe Digital Output Module

Product Overview

  • The Honeywell FC-SDOL-0448 is a Safe Digital Output Module designed for use in Honeywell’s Safety Manager and Fail-Safe Controller (FSC) systems, integral to the TDC 3000 and Experion Process Knowledge System (PKS) platforms. This module provides four independent, loop-monitored digital output channels, delivering 48 VDC solid-state source outputs with short-circuit protection. It is ideal for safety-critical industrial automation applications, such as emergency shutdown (ESD) systems, in industries like oil and gas, chemical, and power generation.

Technical Specifications

  • The FC-SDOL-0448 has the following specifications based on standard characteristics for this model:
Specification Details
Model/Part Number FC-SDOL-0448
General Type Numbers FS-SDOL-0448, FC-SDOL-0448
Manufacturer Honeywell
Description Safe Digital Output Module, 48 VDC, 0.5 A, 4 Channels
Series Safety Manager / FSC / TDC 3000 / Experion PKS
Approvals CE, TUV, UL, CSA
Space Requirements 4 TE, 3 HE (4 HP, 3U)
Power Requirements 5 VDC, 15 mA
48 VDC internal, 25 mA
48 VDC external, 15 mA (without output load)
Output Channels 4
Output Specification 48 VDC solid-state source, short-circuit proof
Maximum Channel Current 0.5 A
Maximum Load Inductance 1 H
Maximum Load Capacitance 0.5 μF
Top of Overload Detection > 50 Ω
Cold Resistance Lamp > 90 Ω
Voltage Drop < 1.5 V at 0.5 A
Off Current < 0.1 mA
Current Sense Voltage Drop < 1 V at 0.5 A
WDG Input Current 4 mA
Key Coding Module code: Holes A17, C9
Chassis code: Large pins A17, C9

Additional Details

  • The FC-SDOL-0448 includes the following additional information based on its standard use and documentation:
  • Function: Provides safe, loop-monitored digital outputs for controlling external devices like solenoids, lamps, or relays, with continuous monitoring for short circuits and overloads to ensure operational safety.
  • Mounting: Installs in Safety Manager or FSC system racks, designed for compact integration with a footprint of 4 TE and 3 HE.
  • Compatibility: Compatible with Honeywell’s Safety Manager, FSC, TDC 3000, and Experion PKS systems; integrates with other safety modules for comprehensive control solutions.
  • Configuration: Supports SIL 2/3 safety applications; key coding (holes and pins at A17, C9) ensures correct module installation to prevent mismatch errors.
  • Certifications: Certified by CE, TUV, UL, and CSA for use in safety-critical environments.
  • [](https://www.topbrandsplc.com/products/honeywell-fc-sdol-0424-4-channel-digital-output-module)

 

Vollständige Details anzeigen

Product Description

Honeywell FC-SDOL-0448 Safe Digital Output Module

Product Overview

  • The Honeywell FC-SDOL-0448 is a Safe Digital Output Module designed for use in Honeywell’s Safety Manager and Fail-Safe Controller (FSC) systems, integral to the TDC 3000 and Experion Process Knowledge System (PKS) platforms. This module provides four independent, loop-monitored digital output channels, delivering 48 VDC solid-state source outputs with short-circuit protection. It is ideal for safety-critical industrial automation applications, such as emergency shutdown (ESD) systems, in industries like oil and gas, chemical, and power generation.

Technical Specifications

  • The FC-SDOL-0448 has the following specifications based on standard characteristics for this model:
Specification Details
Model/Part Number FC-SDOL-0448
General Type Numbers FS-SDOL-0448, FC-SDOL-0448
Manufacturer Honeywell
Description Safe Digital Output Module, 48 VDC, 0.5 A, 4 Channels
Series Safety Manager / FSC / TDC 3000 / Experion PKS
Approvals CE, TUV, UL, CSA
Space Requirements 4 TE, 3 HE (4 HP, 3U)
Power Requirements 5 VDC, 15 mA
48 VDC internal, 25 mA
48 VDC external, 15 mA (without output load)
Output Channels 4
Output Specification 48 VDC solid-state source, short-circuit proof
Maximum Channel Current 0.5 A
Maximum Load Inductance 1 H
Maximum Load Capacitance 0.5 μF
Top of Overload Detection > 50 Ω
Cold Resistance Lamp > 90 Ω
Voltage Drop < 1.5 V at 0.5 A
Off Current < 0.1 mA
Current Sense Voltage Drop < 1 V at 0.5 A
WDG Input Current 4 mA
Key Coding Module code: Holes A17, C9
Chassis code: Large pins A17, C9

Additional Details

  • The FC-SDOL-0448 includes the following additional information based on its standard use and documentation:
  • Function: Provides safe, loop-monitored digital outputs for controlling external devices like solenoids, lamps, or relays, with continuous monitoring for short circuits and overloads to ensure operational safety.
  • Mounting: Installs in Safety Manager or FSC system racks, designed for compact integration with a footprint of 4 TE and 3 HE.
  • Compatibility: Compatible with Honeywell’s Safety Manager, FSC, TDC 3000, and Experion PKS systems; integrates with other safety modules for comprehensive control solutions.
  • Configuration: Supports SIL 2/3 safety applications; key coding (holes and pins at A17, C9) ensures correct module installation to prevent mismatch errors.
  • Certifications: Certified by CE, TUV, UL, and CSA for use in safety-critical environments.
  • [](https://www.topbrandsplc.com/products/honeywell-fc-sdol-0424-4-channel-digital-output-module)

 